Heavy Duty Drag Chain HXSD-HD

The HXSD-HD range is the heavy series: ten models across five inner heights from 38 to 85 mm, each height offered as a bridge chain and as a fully enclosed chain. Load ratings run from 20 to 83 kg per metre. This is the range for machine tools, steel plant, foundry equipment, gantries and anything where the cable bundle contains large hoses under pressure.

Five heights, two forms, ten series

HXSD heavy duty range, dimensions in mm
SeriesInner heightInner widthBend radiusPitchLinks per mOuter heightMax cable diameterMounting heightLoad capacity
HXSD35A38 mm50 to 400 (14 widths)R63 - R30063 mm1656.6 mmØ34 mmH + 5420 kg/m
HXSD35B38 mm50 / 60 / 75 / 90 / 100 / 125R125 - R30063 mm1656.6 mmØ34 mmH + 5420 kg/m
HXSD3545 mm50 to 400 (14 widths)R75 - R30072 mm1467 mmØ40 mmH + 6745 kg/m
HXSD3645 mm50 to 200 (9 widths)R100 - R30072 mm1467 mmØ40 mmH + 6745 kg/m
HXSD3958 mm50 to 400 (14 widths)R100 - R35072 mm1479 mmØ55 mmH + 7965 kg/m
HXSD4058 mm50 to 200 (9 widths)R125 - R35072 mm1479 mmØ55 mmH + 7965 kg/m
HXSD4160 mm75 to 500 (16 widths)R135 - R35091 mm1188 mmØ55 mmH + 8870 kg/m
HXSD4260 mm75 to 300 (8 widths)R135 - R35091 mm1188 mmØ55 mmH + 8870 kg/m
HXSD4385 mm75 to 500 (20 widths)R150 - R600111 mm9110 mmØ75 mmH + 10883 kg/m
HXSD4485 mm100 / 125 / 150 / 200 / 250 / 300R200 - R600111 mm9110 mmØ75 mmH + 10883 kg/m

Material is PA6 with 30 percent glass fibre, black, rated minus 20 to plus 125 degrees Celsius. All series open on both sides.

Bridge and enclosed come in pairs

Every inner height has two models: a bridge version with open cross bars and an enclosed version with a cover. Knowing the pairs saves a lot of catalogue reading.

  • 38 mm: HXSD35A bridge, HXSD35B enclosed
  • 45 mm: HXSD35 bridge, HXSD36 enclosed
  • 58 mm: HXSD39 bridge, HXSD40 enclosed
  • 60 mm: HXSD41 bridge, HXSD42 enclosed
  • 85 mm: HXSD43 bridge, HXSD44 enclosed

The pairs are not identical apart from the cover. The enclosed version always starts at a larger minimum radius, because the cover needs room to swing through the bend. At 38 mm the bridge chain goes down to R63 while the enclosed one starts at R125. That gap decides the choice more often than the ingress protection does: if the machine envelope allows only a small radius, the enclosed version may simply not be available at that radius, and the answer is a sealed cable rather than an enclosed chain.

Load capacity and why overload is expensive

The ratings run 20 kg/m at 38 mm, 45 kg/m at 45 mm, 65 kg/m at 58 mm, 70 kg/m at 60 mm and 83 kg/m at 85 mm. Those figures refer to the weight of the moving bundle per metre of chain, including hoses full of fluid, not the total machine load.

Pin wear does not scale with load, it scales with the cube of load. Running a 20 kg/m chain at 26 kg/m is a 30 percent overload that produces roughly two and a half times the wear rate at the pins. The chain does not fail suddenly; it develops clearance, starts to run off true, and takes the cables with it. This is why we ask for the filled hose weight rather than accepting an estimate from the assembly drawing.

Where the bundle genuinely exceeds the rating, the answer is a bigger height, not a bigger width. Width buys channel area; height buys the bending geometry that determines whether the chain can carry its own weight over the span.

Bend radius and clear height

Clear height above the mounting plane is approximately 2R plus the outer height. At the smallest radii that gives 182 mm for the 38 mm series at R63, 317 mm for the 60 mm series at R135, and 410 mm for the 85 mm series at R150. At the top of the range, R600 on the 85 mm series needs 1,310 mm of clear height.

The radius is set by the stiffest item in the bundle, which on a machine tool is usually the servo or feedback cable rather than the coolant hose. Hose is more flexible than expected; chain-rated cable is less flexible than its datasheet suggests once the machine is cold. Confirm the radius against the cable manufacturer's chain rating before fixing the chain geometry.

Separators, combs and staying out of trouble

Heavy bundles need vertical separators to keep cables from stacking, and the heavy range is also where comb plates with C-profile slots are used at both connectors to hold the bundle in position. Two rules matter:

  • Total fill should stay at or below 55 percent of channel cross section, and below 50 percent for continuously moving axes. Above 70 percent the cables grind rather than slide.
  • Never stack round cables more than 1.5 diameters high without a vertical separator. The lower cable then carries the weight of the stack and its jacket wears through at the contact line.

Inspection thresholds worth putting in a maintenance sheet: pin gap above 0.3 mm, side wall loss of one third, sag of 2 mm below the straight line, or deflection above 3 percent of span. Any one of those means replace, and replacing before cable damage is what keeps the repair to the price of a chain.

Ordering

Series, inner height, inner width, radius and link count, for example HXSD39-58-150-R200L-N8, with connectors supplied as a matched set for the moving and fixed end. For heavy enquiries send the stroke, the bundle weight filled, the maximum hose diameter and the ambient conditions. Those four numbers decide the height, and the height decides everything else.

Related technical articles

Selection guides, installation notes and application cases related to Heavy Duty Drag Chain HXSD-HD.